OTC焊機CPVE400出(chu)現以(yi)下(xia)故(gu)障(zhang)時可以(yi)參(can)照(zhao)本文給(gei)出(chu)的解決(jue)辦法(fa)先自行排(pai)查一(yi)下(xia)故(gu)障(zhang),
OTC焊(han)機CPVE400故障現像1:
出(chu)現電源開(kai)關跳閘(zha)且無法再(zai)次通電這個時候請(qing)不要(yao)擅(shan)自解決此(ci)故障(zhang)請(qing)與當地(di)的正規售后服務公(gong)司聯系。
OTC焊機CPVE400故(gu)障(zhang)現(xian)像2:
主電源(yuan)指(zhi)示(shi)燈(deng)(PL1)不亮,開啟電源(yuan)開關,數(shu)字顯示(shi)表亮燈(deng),大(da)部分情況下是指(zhi)示(shi)燈(deng)(PL1)故(gu)障,我們只(zhi)需要檢查指(zhi)示(shi)燈(deng)PL1就(jiu)行,基本(ben)上換一個(ge)這個(ge)燈(deng)就(jiu)可以解(jie)決些(xie)問題;主電(dian)源指示(shi)(shi)燈(PL1)不(bu)亮,開啟電(dian)源開關,數字(zi)顯(xian)示(shi)(shi)表無任(ren)何顯(xian)示(shi)(shi),風機(ji)不(bu)工作。一(yi)般(ban)出(chu)現這種(zhong)(zhong)(zhong)現像就是焊機(ji)沒有(you)通電(dian)有(you)兩種(zhong)(zhong)(zhong)情況,第一(yi)種(zhong)(zhong)(zhong)是未(wei)開啟配(pei)電(dian)箱的開關我們(men)檢查一(yi)下配(pei)電(dian)箱,第二種(zhong)(zhong)(zhong)情況下輸(shu)(shu)入電(dian)纜(lan)(lan)連(lian)接不(bu)牢靠 檢查輸(shu)(shu)入電(dian)纜(lan)(lan).
OTC焊(han)機CPVE400故障現像3:
開啟電源開關但數字顯示(shi)(shi)表(biao)無任何顯示(shi)(shi)且主電源指(zhi)示(shi)(shi)燈(PL1)不(bu)亮解(jie)決辦法是參(can)照上(shang)面說的解(jie)決辦法;開(kai)啟(qi)電(dian)(dian)源開(kai)關但數字顯示表無任何顯示但PL1亮(liang)燈,這個是控制電(dian)(dian)路(lu)故障我們(men)可(ke)以檢查、更換線路(lu)板P30110Q或(huo)P30110P這(zhe)兩塊板子(zi),基本(ben)上可以解決此問題。
OTC焊(han)機CPVE400故(gu)障現像4:
按焊槍開關(guan)(guan)但無氣(qi)(qi)(qi)體(ti)流出并且按檢氣(qi)(qi)(qi)按鍵也無氣(qi)(qi)(qi)體(ti)流出我(wo)們檢查下氣(qi)(qi)(qi)瓶閥門(men)未開(關(guan)(guan)閉),打開閥門(men),如果故障還有可(ke)以檢查一下是(shi)否(fou)是(shi)氣(qi)(qi)(qi)瓶壓力不足,如果還沒有解決我(wo)們再檢查下看看是(shi)不是(shi)氣(qi)(qi)(qi)體(ti)電磁閥SOL故障.
按(an)焊(han)槍開關但(dan)(dan)無(wu)氣(qi)(qi)體(ti)流出但(dan)(dan)按(an)檢氣(qi)(qi)按(an)鍵(jian)有氣(qi)(qi)體(ti)流出,我(wo)們需要檢查焊(han)槍開關電纜斷線或插座接(jie)觸不良這方面(mian)的故障,檢查線號(hao)151、152即可。
OTC焊(han)機CPVE400故障現像(xiang)5:
按焊槍開關有氣體流出(chu),但無空載電壓,這里有兩種情況,一種是控(kong)制(zhi)電路故障,我們需(xu)要檢(jian)查、更換線(xian)路板P30110P或
P30066S,如(ru)果故(gu)障還沒(mei)有(you)解除(chu)說明不(bu)是(shi)(shi)這個控(kong)制電路故(gu)障,那就是(shi)(shi)第二種情(qing)況了是(shi)(shi)焊(han)機的(de)逆變主電路故(gu)障,不(bu)要擅自解決此(ci)故(gu)障請與當(dang)地的(de)正規售后服務公司(si)聯系。
OTC焊機(ji)CPVE400故障現(xian)像6:
無法(fa)設定電(dian)流(liu)、電(dian)壓,有四(si)種可(ke)(ke)能會(hui)導致此故障現像。可(ke)(ke)能一(yi)控(kong)(kong)制電(dian)路(lu)(lu)故障 我們(men)需(xu)(xu)要(yao)檢查(cha)(cha)、更(geng)換線路(lu)(lu)板P30110P;可(ke)(ke)能性(xing)二濾波(bo)電(dian)路(lu)(lu)故障,我們(men)需(xu)(xu)要(yao)檢查(cha)(cha)、更(geng)換線路(lu)(lu)板 P30110R;可(ke)(ke)能性(xing)三是(shi)遙控(kong)(kong)盒故障我們(men)需(xu)(xu)要(yao)檢查(cha)(cha)及更(geng)換電(dian)纜、插座、遙控(kong)(kong)盒本體;最(zui)后一(yi)種可(ke)(ke)能是(shi)電(dian)壓檢測異常,我們(men)需(xu)(xu)要(yao)檢查(cha)(cha)線路(lu)(lu)板P30110P的CN5 連接狀況(kuang).
OTC焊機CPVE400故(gu)障現(xian)像7:
不送絲,出現這種故(gu)(gu)(gu)障(zhang)(zhang)有可能(neng)(neng)是(shi)以(yi)下幾種情況(kuang)導致的,情況(kuang)一送絲機(ji)側(ce)控制電(dian)纜接觸不良、斷(duan)線(xian)(xian),我(wo)們檢查(cha)、更(geng)(geng)換(huan)插座、電(dian)纜看看能(neng)(neng)不能(neng)(neng)解決(jue)問題,如果故(gu)(gu)(gu)障(zhang)(zhang)依(yi)然存在,那(nei)有可能(neng)(neng)是(shi)電(dian)機(ji)控制電(dian)路(lu)故(gu)(gu)(gu)障(zhang)(zhang)我(wo)們檢查(cha)、更(geng)(geng)換(huan)線(xian)(xian)路(lu)板 P30110Q,如果故(gu)(gu)(gu)障(zhang)(zhang)還在,那(nei)就是(shi)濾(lv)波(bo)電(dian)路(lu)故(gu)(gu)(gu)障(zhang)(zhang)我(wo)檢查(cha)、更(geng)(geng)換(huan)線(xian)(xian)路(lu)板 P30110R。
OTC焊機CPVE400故障現像8:
WCR持(chi)續動(dong)作,導致這個(ge)故障(zhang)的(de)(de)有以下三個(ge)可(ke)(ke)能(neng),可(ke)(ke)能(neng)一電(dian)流霍爾元(yuan)件CT2故障(zhang),我(wo)們(men)檢(jian)(jian)查電(dian)流霍爾元(yuan)件CT2,可(ke)(ke)能(neng)二WCR繼電(dian)器(qi)的(de)(de)故障(zhang)我(wo)們(men)檢(jian)(jian)查、更換線路板(ban)P30110P上的(de)(de)繼電(dian)器(qi);可(ke)(ke)能(neng)三是(shi)WCR電(dian)路故障(zhang)那我(wo)們(men)檢(jian)(jian)查、更換線路板(ban)P30110。
OTC焊(han)機CPVE400故(gu)障現像9
焊機(ji)發(fa)生異常(chang),出現了異常(chang)代碼(ma):E000、E010、E100、E150、E160、E200、E210、E220、E300、E700、E710時。
OTC焊機(ji)CPVE400的故障及(ji)解決(jue)辦法(fa)就說到這里,希望(wang)能給您(nin)帶來幫助,同(tong)時如果您(nin)需要購買OTC的任何配件,都可以與我(wo)聯系,我(wo)公(gong)司是(shi)OTC指定的代(dai)理商,所有配件保證原裝正品(pin),聯系電話:180-9663-1656.
公(gong) 司:安徽歐杰自動化科技(ji)有限(xian)公(gong)司
聯系人:方經理
電話:
手機:180-9663-1656
E-mail:
地 址(zhi):安徽省合肥市望江西(xi)路502號